Impact

OpenManage Enterprise fails to neutralize special elements in output consumed by a downstream component, letting a high-privileged adjacent-network user inject script there. Dell scores confidentiality, integrity and availability all high, so the injection lands somewhere with real authority rather than in a cosmetic field; the advisory does not identify the downstream component. Practically this is an admin-to-admin or admin-to-component escalation path inside the management console that runs the fleet's firmware and power workflows.

Who can reach it

Adjacent-network access to the OME console with an administrator-level account. Authentication required.

What to do

Upgrade to OpenManage Enterprise 4.8.0 (DSA-2026-467): appliance update and console restart. Managed nodes need no action. No interim workaround is published.

References

Related entries

All Firmware, BMC & network fabric entries

This entry is curated: imported from vendor advisories with machine assistance, not yet individually verified. Confirm against your vendor's advisory before acting, and report anything wrong.