GPU VulnDB

Database/Kernel, userspace & hypervisor

VMware vCenter: unauthenticated authentication bypass in the VMware Directory Service

CVSS 9.8CVE-2026-123890Kernel, userspace & hypervisorcurated

Impact

An attacker can bypass authentication in the VMware Directory Service, the identity store vCenter uses to authenticate users and services. The vendor rates it 9.8 with no privileges and no user interaction, which points to full control of the vCenter management plane. Whoever controls vCenter controls every ESXi host and VM it manages, including GPU VMs with passthrough or vGPU devices, so one compromised vCenter puts the whole virtualized fleet at risk. The record does not say what an attacker can do after the bypass beyond the CVSS rating. Telco Cloud Platform and Telco Cloud Infrastructure deployments are also affected.

Who can reach it

Anyone with network access to the vCenter Server appliance. No authentication needed. Exposure depends on whether vCenter is reachable only from an isolated management network.

What to do

Upgrade vCenter to 9.1.1.0200 (9.1.x), 9.0.2.0200 (9.0.x), 8.0 U3m (8.0) or 5.2.5 (5.x). For Telco Cloud Platform 3.0, 4.x, 5.0.x, 5.1.x and 5.2, and Telco Cloud Infrastructure 3.0, follow Broadcom KB463116. Updating the vCenter appliance takes the management plane down for the update window. VMs and ESXi hosts keep running, but vMotion, provisioning and other management actions are unavailable until it finishes. Until it is patched, limit network access to vCenter to the management network.

References

Related entries

All Kernel, userspace & hypervisor entries

This entry is curated: imported from vendor advisories with machine assistance, not yet individually verified. Confirm against your vendor's advisory before acting, and report anything wrong.