Linux bnxt_en driver (TX BD bd_cnt field masking): The 5-bit bd_cnt field in the transmit buffer descriptor
Impact
The 5-bit bd_cnt field in the transmit buffer descriptor is not masked, so an out-of-range value corrupts transmit descriptors and produces TX timeouts. Practically: the NIC stops transmitting. On a training node that is a hung collective, and the failure looks like a network problem rather than a driver bug, so it burns debugging time.
Who can reach it
Triggered by transmit paths that produce a descriptor count above the representable range. Local, driven by workload traffic patterns.
What to do
Kernel/driver upgrade plus host reboot. No firmware change required.
References
Related entries
- Intel AMT and Intel Standard Manageability firmware (current CSME generations): Out-of-bounds write in AMT/ISM firmwareCVE-2025-32008 · Intel AMT and Intel Standard Manageability firmware (current CSME generations)High
- Eaton UPS Companion (EUC) software installer: The installer does not properly authenticate the library files it loadsCVE-2025-59887 · Eaton UPS Companion (EUC) software installerHigh
- Eaton Tripp Lite series PADM firmware (rack PDU / ATS management): Unauthenticated authentication bypass givesCVE-2026-22620 · Eaton Tripp Lite series PADM firmware (rack PDU / ATS management)High
- Arista EOS: crafted gNSI Credentialz request can grant an account privileges beyond what was configuredCVE-2026-73454 · Arista EOS gNSI Credentialz serviceHigh
- InfiniBand / RoCEv2 transport - RNIC connection state (QP number, PSN) on Mellanox ConnectX-class and compatible RNICsNCVD-2021-003-infiniband-rocev2-transport-rnic · InfiniBand / RoCEv2 transport - RNIC connection state (QP number, PSN) on Mellanox ConnectX-class and compatible RNICsHigh
- InfiniBand / RoCEv2 transport - RNIC connection state (QP number, PSN) on Mellanox ConnectX-class and compatible RNICsNCVD-2021-009-infiniband-rocev2-transport-rnic · InfiniBand / RoCEv2 transport - RNIC connection state (QP number, PSN) on Mellanox ConnectX-class and compatible RNICsHigh
This entry is curated: imported from vendor advisories with machine assistance, not yet individually verified. Confirm against your vendor's advisory before acting, and report anything wrong.