GPU VulnDB

Database/Firmware, BMC & network fabric

SonicWall SonicOS SSLVPN: no limit on MFA code attempts

CVSS 8.8CVE-2023-1101Firmware, BMC & network fabriccurated

Impact

SSLVPN does not limit how many MFA codes an authenticated user can try. Someone who already holds a valid password can keep guessing second-factor codes until one works. That defeats MFA on the VPN that may front cluster management access. The record gives no detail beyond this.

Who can reach it

Remote. The attacker needs valid first-factor credentials for the SSLVPN.

What to do

Upgrade SonicOS to the fixed firmware in SNWLID-2023-0005. That is a firewall firmware upgrade and reboot, or a failover to an HA peer. Until then, watch for repeated MFA failures and rotate any VPN passwords you suspect are exposed.

References

Related entries

All Firmware, BMC & network fabric entries

This entry is curated: imported from vendor advisories with machine assistance, not yet individually verified. Confirm against your vendor's advisory before acting, and report anything wrong.